Infrastructure:APC RackPDU: Difference between revisions

From Research
Jump to navigation Jump to search
No edit summary
No edit summary
Line 4: Line 4:
* [http://www.apc.com/resource/include/techspec_index.cfm?base_sku=AP7900 AP7900]
* [http://www.apc.com/resource/include/techspec_index.cfm?base_sku=AP7900 AP7900]
* [??? MasterSwitch VM]
* [??? MasterSwitch VM]


===Details===
===Details===
Line 10: Line 11:
** IP range 192.168.254.NNN where NNN is the unit number.
** IP range 192.168.254.NNN where NNN is the unit number.
** Access details same as [[Infrastucture:GigSwitchStack|GigSwitchStack]]
** Access details same as [[Infrastucture:GigSwitchStack|GigSwitchStack]]
* SNMP MIB is here: ftp://ftp.apcc.com/apc/public/software/pnetmib/mib/368/powernet368.mib


===Device List===
===Device List===
Line 19: Line 21:
** APC05 - node085 to node106, 2 unlabeled outlets
** APC05 - node085 to node106, 2 unlabeled outlets
** APC06 - node109,112,115,118,121,124,127 and 17 unlabeled outlets
** APC06 - node109,112,115,118,121,124,127 and 17 unlabeled outlets
* The following units are in the Research Server room, and are AP7900 units.
* The following units are in the Research Server room, and are AP7900 units. None of the outlets are labelled.
** APC07 - Primary infrastucture rack
** APC07 - Primary infrastucture rack
** APC08 - Primary infrastucture rack
** APC08 - Primary infrastucture rack
Line 26: Line 28:
** APC11 - Far-left rack
** APC11 - Far-left rack
** APC12 - Far-left rack
** APC12 - Far-left rack
** APC13 - offline, intended for switch stack
** APC13 - switch stack
** APC14 - offline, intended for switch stack
** APC14 - switch stack
** APC15 - for beige boxes, located on shelving
** APC15 - for beige boxes, located on shelving


===Monitoring===
===Monitoring===
* TODO - via SNMP, and present data on webpage.
All data is fed into Nagios for monitoring. Units are tenth of an Amp (so 81 = 8.1A). Warning level is 9.0A, Critical level is 10.0A.

Revision as of 01:57, 1 June 2005

We have a total of 15 APC Power Distribution Units. These allow for remote power monitoring and cycling for all connected devices.

Specifications


Details

Device List

  • The following units are connected to Nebula, and are all MasterSwitch VM units.
    • APC01 - node001 to node022, 2 unlabeled outlets
    • APC02 - node023 to node044, 2 unlabeled outlets
    • APC03 - nodes057,060,063, 21 unlabelled outlets
    • APC04 - node064 to node084, 4 unlabeled outlets
    • APC05 - node085 to node106, 2 unlabeled outlets
    • APC06 - node109,112,115,118,121,124,127 and 17 unlabeled outlets
  • The following units are in the Research Server room, and are AP7900 units. None of the outlets are labelled.
    • APC07 - Primary infrastucture rack
    • APC08 - Primary infrastucture rack
    • APC09 - Central rack
    • APC10 - Central rack
    • APC11 - Far-left rack
    • APC12 - Far-left rack
    • APC13 - switch stack
    • APC14 - switch stack
    • APC15 - for beige boxes, located on shelving

Monitoring

All data is fed into Nagios for monitoring. Units are tenth of an Amp (so 81 = 8.1A). Warning level is 9.0A, Critical level is 10.0A.